| GUARDIAN® home standby generators
automatically supply electricity to pre-selected circuits during a utility power
outage. Our pre-packaged,
pre-wired systems make installation fast, easy and so affordable, you’ll
wonder why you didn’t buy one sooner! And with GUARDIAN, the kilowatt
ratings we list… are the kilowatt ratings you get. Unlike our
competitors who only cover a percentage of the standby loads, GUARDIAN
covers the entire load, for the full duration of the power outage. 7, 10 and 13 kW Air-Cooled Standby Generators
|
Generator Sets:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Controls
| Engine Start Sequence | Cyclic cranking: 7 sec. on, 7 sec. rest. 90 sec. maximum duration |
| Automatic Low Oil Shutdown | Standard |
| Overspeed Shutdown | Standard, 72 Hz |
| Overcrank Protection | Standard |
| Automatic Voltage Regulator with Over-Voltage Protection | Standard |
| Engine Warmup | 10 seconds |
| Engine Cool-Down | 1 minute |
| Safety Fuse | Standard |
| 2.5 Amp Timed Trickle Battery Charger | Standard |
| Auto Switch | Automatic start on utility failure/7 day exercise |
| Off Switch | Stops unit. Power is removed. Control and charger still operate |
| Manual / Test (start) | Start with starter control, unit stays on. If utility fails, transfer to load takes place |
| Full Monitoring System | Oil pressure, coolant temperature, engine speed, coolant level, cranking time, starter lockout, utility sensing |
| Shutdown and LED Indicators | overspeed and overcrank, low oil pressure, high coolant temperature, low coolant level, low fuel pressure, low battery voltage |
Transfer Switches
| No. of Poles | 2 | ||||||
| Current Rating (amps) | 100 | ||||||
| Voltage Rating (VAC) | 250 | ||||||
|
|||||||
| Return to Utility | Approx. 13 seconds | ||||||
| Exercised 7 minutes weekly | Standard | ||||||
| UL Listed | Yes | ||||||
| Dimensions (H" x W" x D") | 26.5 x 12.5 x 7 | ||||||
|
7 kW Air-Cooled Standby Generator
There’s no need to worry about individual items because everything on the circuits you choose is protected… lights, plug-in appliances, electronics, air conditioner… everything! Plus, GUARDIAN’s 7 kW comes as a pre-packaged, pre-wired system, so it’s the easiest system on the market to install. That’s just one more reason why GUARDIAN is America’s #1 selling brand.
Controls 7 kW
Transfer Switch 7 kW
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Features and Benefits Breakthrough Design, Advanced TechnologyGUARDIAN® and GUARDIAN QuietSource™ air-cooled generators offer the most wattage and greatest starting power in their class. The GUARDIAN QuietSource 16 kW can start a 5-ton and 3-ton A/C unit or two 4-ton units. The 13 kW can start a 4-ton and the 10 kW can start a 3-ton. Whisper-Test™ (GUARDIAN QuietSource models only) Reduces noise to a whisper by lowering engine speed during the generator’s weekly self-test. The Whisper-Test sound level is comparable to a car at idle and is 50% quieter (59 dBA) than the competition. Pre-wired and Pre-packaged GUARDIAN’s pre-packaged, pre-wired air-cooled systems make installation easy and, therefore, incredibly affordable for the do-it-yourselfer! Air-cooled models come with a pre-wired automatic transfer switch, outdoor connection box and composite mounting pad. OHVI® Industrial Engine Generac’s OHVI® (Overhead Valve Industrial) engines have been specifically designed for generator demands. These engines offer the finest lubrication technology available providing instantaneous disbursement of lubricant to all engine parts. They also feature an automotive spin-on oil filter for simplified routine maintenance. Superior Electrical Protection The air-cooled 10, 13 and 16 kW models feature an electronic governor, which maintains steady speed and eliminates voltage drop when loads are applied. This, as well as the automatic voltage regulator, provides a smooth rate of electricity, which is especially important for sensitive electronic devices such as computers. Superior Paint New textured, powder coat paint process provides consistent coverage and better bonding to seams and exposed edges providing durability and a long-lasting, tough finish. Aluminum Enclosure (optional on GUARDIAN QuietSource models) GUARDIAN QuietSource generators are available in a corrosion-resistant aluminum enclosure to better withstand the elements. This option is especially important for homes in southern and coastal communities. Automatic Exerciser An automatic seven (7) day test of your system allows you to verify that your generator is in peak operating condition at all times. Automatic Transfer Switch The automatic transfer switch automatically switches the source of power from the utility to the generator within seconds of a power outage. Because it’s automatic, you never have to flip a switch. Convenient Fuel Supply GUARDIAN and GUARDIAN QuietSource generators operate on natural gas or LP gas service. This provides you with unlimited run time during extended utility power failures. Maintenance Friendly Air-cooled models feature a hinged top and removable front panel. Liquid-cooled models feature large, removable doors. This provides easy and quick access for maintenance and servicing. Automatic Safety Shutdowns Automatic safety shutdowns protect the engine and generator in the event of low oil pressure, high temperature, overspeed and/or overcrank. Protective Enclosure The enclosure protects your generator from harmful weather and includes key locks for security. Sound-absorbing panels also reduce exterior noise levels. Battery Charger A built-in battery charger ensures that the battery remains at an optimum performance level. Easy Installation GUARDIAN’s air-cooled pre-packaged, pre-wired systems make installation the most affordable and easiest installation possible. UL-Listed For your safety, GUARDIAN standby generators are UL 2200 listed and all transfer switches are UL 1008 listed. This validates safety and kilowatt ratings. EPA and CARB Emission Requirements Generators up to 25kW must comply with EPA and CARB emissions requirements. All GUARDIAN generators up to 25 kW meet these requirements. Made in USA Manufactured by Generac Power Systems, we design and build our complete product from the controls to the enclosures, to our air-cooled engines specifically designed for generators. This ensures that all GUARDIAN and GUARDIAN QuietSource products are built to our highest standards. |
|
|
|
|
| GUARDIAN Power Rating | Bulletin Number |
|---|---|
| 7, 10 & 13 kW Air-Cooled | 0F9424 |
| 40 kW Liquid-Cooled (California Emissions) | 0D5335 |
| GUARDIAN QuietSource Power Rating | Bulletin Number |
|---|---|
| 16 kW Air-Cooled | 0F9424 |
| GUARDIAN
QuietSource Liquid-Cooled (20-45kW) and GUARDIAN Elite Commercial Series Liquid-Cooled Power Rating: |
Bulletin Number |
|---|---|
| 20kW 1.5L | 0F7555A-A |
| 20kw and 25kW 1.6L | 0G1044-A |
| 35kW and 45kW 2.4L | 0G0325-B |
| 60kW | 0F9577-B |
| 70kW 6.8L | 0F6287-B |
| 80kW 4.6L | 0G1088 |
| 80kW 5.4L thru 150kW | 0F6289-B |
The transfer switch monitors utility power and signals the generator to
start when utility power is interrupted. When utility power returns, the
transfer switch returns the electrical load from the generator back to the
utility. This ensures your most important electrical loads are powered,
within seconds, even when you’re away. Unlike other pre-packaged
systems, GUARDIAN includes an automatic transfer switch as standard
equipment with all models.This transfer switch is the difference between a truly automatic generator set and just another generator. No toggles to flip, no knobs to turn, no extension cords to run when you lose utility power. You will have the comfort and peace-of-mind knowing that your GUARDIAN standby generator does everything for you... automatically.
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Owners Manuals
| Air-Cooled Models | Complete File | Bulletin # |
|---|---|---|
| Models 4077-0, 4109-0, 4079-0 | 4.0 MB | 0C2369 |
| Models 4077-1, 4109-1, 4079-1 | 4.4 MB | 0C4217 |
| Models 4077-2, 4109-2, 4079-2 | 6.1 MB | 0C9035 |
| Models 4077-3, 4109-3, 4079-3 | 6.1 MB | 0C9036 |
| Models 4389-0, 4456-0, 4390-0 | 4.3 MB | 0D3169 |
| Models 4389-1, 4456-1, 4390-1 | 4.6 MB | 0D8846 |
| Models 4758-0, 4759-0, 4760-0 | 3.7 MB | 0E1370 |
| Models 4389-3, 4456-3, 4390-3 After Serial Number 3999625 | 4.7 MB | 0F3982 |
| Models 4389-2, 4456-2, 4390-2 | 5.2 MB | 0E8012 |
| Models 4758-1, 4759-1, 4760-1 | 4.9 MB | 0E8295 |
| Models 4758-2, 4759-2, 4760-2 | 4.9 MB | 0F0083 |
| Models 4758-2, 4759-2, 4760-2 After Serial Number 3999625 | 4.6 MB | 0F3985 |
| Model 04916-0 | 3.9 MB | 0E4885 |
| Models 05240-0, 05280-0, 05241-0, 05281-0, 05242-0, 05282-0, 05244-0, 05283-0, 05284-0 | 8.4 MB | 0F9421 |
| Liquid-Cooled Models | Complete File | Bulletin # |
|---|---|---|
| Models (Natural Gas)
907-2, 908-2, 909-2, 910-2, 911-2, 912-2, 913-2, 914-2, 4188-0, 4370-0 Models (Liquid Propane) 4112-0, 4113-0, 4114-0, 4115-0, 4116-0, 4117-0, 4118-0, 4119-0, 4189-0, 4371-0 |
6.5 MB | 0C1000 |
| Models (Sound Attenuated) 972-0, 973-0, 974-0, 975-0, 976-0, 977-0, 978-0, 979-0, 2001-0 | 5.2 MB | 0A7218 |
| Models (Natural Gas)
4090-2, 4091-2, 4092-2, 4093-2, 4094-2, 4095-2, 4096-2, 4097-2, 4474-0 Models (Liquid Propane) 4124-1, 4125-1, 4126-1, 4127-1, 4128-1, 4130-1, 4131-1, 4475-0 |
7.1 MB | 0C8840 |
| Models 4123-0, 4144-0, 4145-0, 4146-0, 4373-0 | 5.7 MB | 0C2159 |
| Models 4136-0, 4137-0 | 5.6 MB | 0C2517 |
| Models (Natural Gas)
4188-1, 4370-2, 4474-1 Models (Liquid Propane) 4189-1, 4371-2, 4475-1 |
5.0 MB | 0D6444 |
| Models 4373-1, 4626-0 | 3.6 MB | 0D4963 |
| Models 4373-2, 4626-1 | 5.2 MB | 0D8908 |
| Models 4373-3, 4373-4, 4626-2 | 4.5 MB | 0E1780 |
| Models 4721-0, 4722-0, 4723-0, 4724-0, 4725-0, 4725-1, 4725-2, 4725-3, 4726-0 | 4.1 MB | 0E1151 |
| Models 4988-1 | 5.7 MB | 0F2006 |
| Model 4988-2 | 5.9 MB | 0F5095 |
| Model 4988-4 | 3.8 MB | 0F6866 |
| Models 4992-0, 4992-1 | 5.1 MB | 0E8359 |
| Models 4373-6, 4626-5 | 3.5 MB | 0E7018 |
| Models 05030-1, 05028-1, 05031-0, 5028-0, 5030-0, 5031-1 | 4.5 MB | 0F1007 |
| Model 4917-2 | 5.7 MB | 0E8565 |
| Model 4917-3 | 6.0 MB | 0F5093 |
| Model 4917-4 | 5.8 MB | 0F5546 |
| Model 4917-5 | 5.9 MB | 0F6867 |
| Model 4992-2 | 3.6 MB | 0F4942 |
| Model 05012-0 | 5.1 MB | 0E9042 |
| Model 05012-1 | 3.5 MB | 0F4946 |
| Model 05031-2 | 4.1 MB | 0F5097 |
| Model 05040-2 | 5.7 MB | 0F5098 |
| Models 05054-1, 05053-1, 05040-1 | 4.9 MB | 0F1005 |
| Model 05210-0 | 3.8 MB | 0F7921 |
| Model 05211-0 | 3.8 MB | 0F7909 |
| Model 05212-0 | 3.4 MB | 0F7922 |
| Model 5213-0 | 3.4 MB | 0F7910 |
| Model 5219-0 | 4.4 MB | 0F7923 |
| Model 05220-0 | 4.4 MB | 0F7911 |
| Model 05221-0 | 4.2 MB | 0F7924 |
| Model 05222-0 | 4.2 MB | 0F7912 |
| Model 05259-0 | 4.6 MB | 0G0238 |
| Model 05259-1 | 5.2 MB | 0G0238A |
| Model 05260-0 | 4.6 MB | 0G0239 |
| Model 05260-1 | 5.2 MB | 0G0239A |
| Model 05261-0 | 4.6 MB | 0G0201 |
| Model 05261-1 | 5.0 MB | 0G0201A |
| Model 05262-0 | 4.6 MB | 0G0202 |
| Model 05262-1 | 5.0 MB | 0G0202A |
| Models 05324-0, 05325-0 | 3.9 MB | 0G1260 |
| Models 05336-0 and 05337-0 | 4.17 MB | 0G2966 |
| Liquid-Cooled Models - Guardian Elite Commercial Series | Complete File | Bulletin # |
|---|---|---|
| Model QT020 1.5L | 4.13 MB | 0F7437 |
| Model QT020 1.6L | 4.15 MB | 0G2160 |
| Model QT025 1.6L | 4.13 MB | 0G1135 |
| Model QT035 2.4L | 5.13 MB | 0G1144 |
| Model QT045 2.4L | 5.13 MB | 0G1157 |
| Model QT060 3.0L | 5.34 MB | 0F9665 |
| Model QT070 6.8L | 5.36 MB | 0F3606 |
| Model QT080 4.6L | 5.94 MB | 0G1276 |
| Model QT080 5.4L | 5.85 MB | 0F3608 |
| Model QT100 5.4L | 6.23 MB | 0F3607 |
| Model QT100 6.8L | 6.44 MB | 0F3605 |
| Model QT130 6.8L | 6.37 MB | 0F3604 |
| Model QT150 6.8L | 6.45 MB | 0F3603 |
| Transfer Switches | Complete File | Bulletin # |
|---|---|---|
| Models 4635-3, 4678-2 | 1.0 MB | 0E6347 |
| Model 4635-1, 4635-2 | 1.0 MB | 0E4334 |
| Model 4635-0 | 1.0 MB | 0D4001 |
| Models 9227-0, 9228-0, 9229-0, 9230-0 | 2.1 MB | 078590 |
| Models 9227-2, 4678-1 | 795 KB | 0C3908 |
| Models 9489-0, 9480-0, 9491-0 | 1.8 MB | 086150 |
| Models 4945-1, 5036-0 | 1.0 MB | 0E9905 |
| Model 5239-0 | 573 KB | 0G0734 |
| Models RTSN100A3 and RTSN200A3 | 886 KB | 0F6770 |
| Models RTSE100A3 and RTSE200A3 | 1.0 MB | 0G0399 |
| Technical Manual for R-100 Digital Controller | Complete File | Bulletin # |
|---|---|---|
| For Models 05210-0,
05211-0, 05212-0, 05213-0, 05219-0, 05220-0, 05221-0, and 05222-0 |
0.3 MB | 0F6402 |
| Technical Manual for R-200 Digital Controller | Complete File | Bulletin # |
|---|---|---|
| Models 05259-1, 05260-1, 05261-1, 05262-1, 05324-0, 05325-0, 05336-0 and 05337-0 | 260 KB | 0G1341 |
| Installation Manual | Complete File | Bulletin # |
|---|---|---|
| For Models 05210-0,
05211-0, 05212-0, 05213-0, 05219-0, 05220-0, 05221-0, 05222-0, 05259-0, 05259-1, 05260-0, 05260-1, 05261-0, 05261-1, 05262-0, 05262-1, 05324-0, 05325-0, 05336-0, 05337-0 and 05340-0 |
650 KB | 0F9849 |
| Service, Diagnostic and Parts Manuals | Complete File | Bulletin # |
|---|---|---|
| Diagnostic Repair Manual for Pre-packaged Home Standby Systems | 14.5 MB | 083045 |
| Diagnostic Repair Manual for Models 5240, 5241, 5242, 5243, 5244, 5280, 5281, 5282, 5283, 5284 | 7.8 MB | 0G2152 |
| Diagnostic Repair Manual for Models 4389, 4390, 4456, 4758, 4759, 4760 | 9.2 MB | 0E3586 |
| Gen II Installation Manual | 4.0 MB | 079699 |
| Diagnostic Repair Manual 1.5L Home Standby Generator Models: 4721,4722,4723,4724,4725,4726 | 3.6 MB | 0F7698 |
| 1.5L Engine Service Manual | 2.0 MB | 0C1947 |
| 1.5L Engine Gas Parts Manual | 1.0 MB | PB15000G |
| 1.6L Engine Service Manual | 3.3 MB | 0A1368 |
| 1.6L Engine Gas Parts Manual | 1.0 MB | PB16000G |
| 2.5L Engine Service Manual | 19.9MB | 0E9693 |
| 3.0L Engine Service Manual | 42.6MB | 0E9267 |
| 3.9L Engine Service Manual | 15.3MB | 0E9755 |
| 4.3L Engine Service Manual | 18.1 MB | 0C8220 |
| 4.3L Engine Gas Parts Manual | 1.6 MB | 0D3749 |
| V-Twin Parts Service Manual (Horizontal and Vertical Shafts) | 12.5 MB | 081134 |
| OHVI V-Twin Engine Service Manual for Model GN724 | 4.5 MB | 0C8221 |
| OHVI V-Twin Engine Service Manual for Model GTV 990/760 | 15.5 MB | 0E2081 |
| Service and Repair Manual for Small Frame GN Engines - Models 190/191/220 | 16.5 MB | 0C1103 |
| Service and Repair Manual for Large Frame GN Engines - Models 320/360/410 | 14.9 MB | 0C1103 |
| Basic Electricity | 0.9 MB | 46941 |
| Controlling Electricity | 0.9 MB | 46961 |