RTS Automatic Transfer Switch 100 - 400 Amps 600 VAC


email


Buy Commercial Generators
Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches   |  Pricing  |  Email

Standard Transfer
Switch Models 04678 & 04635
Service Disconnect
Transfer Switch Models 05036 & 04945

 Model 04678 100 Amps 120/240 Volt 1 phase 
Price:  Call

Model 0 4635
200 Amps 120/208 3 phase
Price:  Call

Model 04678
100 Amps 120/208 3 phase
Price:  Call

Model 04635
200 Amps 277/480 3 phase
Price:  Call

Model 04678
100 Amps 277/480 3 phase
Price:  Call

 Model 04945
200 Amps 120/240 1 phase w/ service disconnect 
Price:  Call

Model 05036
100 Amps
120/240 1 phase w/ service disconnect  
Price:  Call

Model 04945
400 Amps 120/240 1 phase
Price:  Call

Model 04635 
200 Amps 120/240 1 phase 
Price:  Call

Model 04945
400 Amps 120/208 3 phase
Price:  Call

Model 4397 100 Amps ATS with Load Center (LC)-Tan Call to order    Price:  Call              

 

DESCRIPTION

STANDARD FEATURES

Generac RTS automatic transfer switches are designed to operate with the Generac R-100 controller used on the 3.0 and 3.9 liter Guardian Elite gaseous generators.  The transfer switches are UL 1008 listed for standby operation.  The standard 100 - 400 amp transfer switch is housed  in a steel NEMA 3R enclosure with electrostatically applied powder paint.  The Heavy Duty contactor is a UL recognized device, designed for years of service.  The connection between the RTS and the Generator control consists of (4) #14 control wires and a neutral wire. The Service Entrance rated transfer switches have a UL Listed Mainline circuit breaker ahead of the contactor for full downstream protection.

Specifications RTS Automatic Transfer Switch Generac Guardian

FUNCTIONS SPECIFICATIONS TYPICAL CONNECTION RTS 100-400 Amp Transfer Switch All Timing and sensingfunctions originate in the R-100 controller Utility voltage drop-out ...........................................................................................................................................................................<60% Timer to generator start.................................................................................................................................................................15 seconds Engine warm up delay...................................................................................................................................................................10 seconds Standby voltage sensor ...........................................................................................................................................................................90% Utility voltage pickup ...............................................................................................................................................................................>80% Re-transfer time delay ...................................................................................................................................................................15 seconds Engine cool-down timer.................................................................................................................................................................60 seconds Exerciser .................................................................................................................................................................15 minutes every 7 days The transfer switch can be operated manually without power applied. Generator N1 N2 Neutral 23 194 RTS N1 N2 Neutral 23 194 Amps 100 100 200 200 400 400 Voltage 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 120/240, 1ø 277/480, 3ø 120/208, 3ø 120/208, 3ø 120/208, 3ø 277/480, 3ø 277/480, 3ø Load Transition Type Open Transition Open Transition Open Transition Open Transition Open Transition Open Transition (Automatic) Ser. Ent. Rated Ser. Ent. Rated Enclosure Type NEMA 3R NEMA 3R NEMA 3R NEMA 3R NEMA 3R NEMA 3R Express Install Kit Included No No No No No No Withstand Rating (Amps) 10,000 10,000 10,000 10,000 18,000 18,000 Lug Range 400 MCM - #4 600 MCM - #4 or 2-250 MCM External Dimensions (H" x W" x D") 120/240, 1ø & 120/208, 3ø 24 x 20 x 7 24 x 13 x 7 20 x 15 x 7 24 x 13 x 7 36 x 24 x 10 48 x 30 x 12 277/480, 3ø 36 x 24 x 10 Unit Weight (lbs.) 26 42 48 50 95 105 2/0 - #14

 

Typical Connection for RTS Automatic Transfer Switch

 

MODEL 100A-STD 200A-STD 100A-SRV 200A-SRV

MODEL NUMBER 04678 04635 05036 04945

RATED CURRENT 100 AMP 200 AMP 100 AMP 200 AMP

VOLTAGE 120/240V 120/240V 120/240V 120/240V

SERVICE DISCONNECT NA NA 100 AMP 200 AMP

CIRCUIT BREAKER HACR TYPE HACR TYPE

TERMINAL WIRE RANGES

Switch Terminal 1/0 - 14 250MCM - 6 1/0 - 14 250MCM - 6

Neutral Lug 2/0 - 14 350MCM - 6 2/0 - 14 350MCM - 6

Ground Lug #4 - #14 AWG #4 - #14 AWG #4 - #14 AWG #4 - #14 AWG

UL LISTING 1008 1008 1008 1008

UNIT DIMENSIONS (H”xW”xD”)

Height - H1/H2 16.5 / 20.0 16.5 / 20.0 20.75 / 23.5 20.75 / 23.5

Width - W1/W2 11.57 / 15.15 11.57 / 15.15 10.67 / 13.05 10.67 / 13.05

Depth 7.07 7.07 7.36 7.36

UNIT WEIGHT (LBS) 35 35 50 50

SPECIFICATIONS

Specifications subject to

change without notice

TRANSFER SWITCHES

100 AMP AND 200 AMP MODELS

• All switch enclosures are powder paint coated steel

• NEMA 3R (Outdoor rated)

FEATURES

• 2 pole 250 VAC contactors

• 160 millisecond transfer time when contactor is energized

• Dual coil design

• Main contacts are silver plated or silver alloy to resist welding and sticking

AUTOMATIC OPERATION

When used in conjunction with one of the Generac home standby generators, the transfer switch

receives its signal from the generator control circuit to provide safe and dependable transfer from

utility to standby power without any intervention by the owner.

STANDARD

These models are utilized when essential circuits from a home’s main distribution panel are to be

relocated to a separate sub-panel. These critical circuits are then powered by the generator in a

utility failure event.

SERVICE DISCONNECT

These models provide the ability to power a home’s entire distribution panel when relocating

circuits to a separate sub-panel is not practical. Reduces labor related installation costs. Suitable

as service entrance equipment.

C US

UL 1008

LISTED

Standard 100 Amp and

200 Amp NEMA 3R

Service Disconnect 100 Amp

and 200 Amp NEMA 3R

H1 H2

W1

W2

STANDARD SERVICE DISCONNECT

transfer switch dimensions

Transfer Switch Specifications

The heart of the system. RTS 100-400 AMP can be used with the QT Series up to 70 kW V6 engine.  
  • The Quietsource 11 kW air cooled unit can be used with the 4678 (standard Tan) and 5036 (ATS with service disconnect Gray).
  • The Quietsource 20 kw, 25 kW, 30 kW and 40 kW should be used with the 200 amp (Standard Tan) or the 200 AMP (ATS with disconnect)

RTS 100-400 AMP Designed for a wide variety of applications that require up to 400 Amps. NEMA 3R models are intended for outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure. RTS transfer switches can only be used with the models listed in the chart to the right. HTS 100-800 AMP Designed for simple monitoring, operation and maintenance. Common controls and LED lights are conveniently located on front door panel. All components are front adjustable and removable for serviceability. HTS transfer switches can only be used with the models listed in the chart to the right. All transfer switches are UL 1008 Listed to meet safety and performance standards. 

Unlike other pre-packaged systems, Generac includes an automatic transfer switch (standard equipment with all models). This device will ensure your vital electrical loads are powered, even when you are not there.

This transfer switch is the difference between a truly automatic generator set and just another generator. No toggles to flip, no knobs to turn, no extension cords to run when you lose utility power. You will have the comfort and peace-of-mind knowing that your Guardian emergency power system does everything for you... automatically.  

A two pole, 100-amp UL-listed automatic switch is standard equipment on models 04721 and 04723.

A two pole, 200-amp UL-listed automatic switch is standard equipment on models 04725 and 04988.

A two pole, 200-amp Service Disconnect transfer switch is standard equipment on model 04992.

Standard Transfer
RTS 100-400 AMP
Switch Models

Standard Transfer Switch Model 04678 and 04635
RTS 100-400
View all RTS transfer switches
BUY ONLINE NOW

 


Service Disconnect Transfer Switch Models 05036 & 04945
Service Disconnect Transfer Switch Models


Generator Ready Kit Model 04397
Generator Ready Kit Model 04397
STANDARD TRANSFER SWITCH
Model Number 04678 04635
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%

80%
60%
Return to Utility 15 seconds 15 seconds
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H"xW"xD") 20x15x7 20x15x7
Enclosure Type NEMA 3R
Outdoor Rated
NEMA 3R
Outdoor Rated
Unit Wt. (lbs.) 35 35

* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.

 
SERVICE DISCONNECT TRANSFER SWITCH
Model Number 05036 04945
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%

80%
60%
Return to Utility 15 seconds 15 seconds
Service Disconnect Circuit Breaker 100 Amp HACR Type 200 Amp HACR Type
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H"xW"xD") 23.5x13x7.4 23.5x13x7.4
Enclosure Type NEMA 3R
Outdoor Rated
NEMA 3R
Outdoor Rated
Unit Wt. (lbs.) 50 50

* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.

 
GENERATOR READY KIT
Model Number 04397
No. of Poles 2
Current Rating (amps) 100
60 Hz Phase Single
Voltage Rating (VAC) 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%
Return to Utility 15 seconds
Exerciser 12 min. weekly † Standard
UL 1008 Listed Standard
Dimensions (H"xW"xD") 26.5x12.5x7
Enclosure Type NEMA 1
Indoor Rated
Unit Wt. (lbs.) 75

† When used with air-cooled standby generator models. No exercise function takes place when used with the Ultra Source portable generators.

transfer switch specifications generac guardian

Specifications subject to change without notice

STANDARD TRANSFER SWITCH
Model Number 04678 04635
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%

80%
60%
Return to Utility 15 seconds 15 seconds
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H"xW"xD") 20x15x7 20x15x7
Enclosure Type NEMA 3R
Outdoor Rated
NEMA 3R
Outdoor Rated
Unit Wt. (lbs.) 35 35

* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.

 
SERVICE DISCONNECT TRANSFER SWITCH
Model Number 05036 04945
No. of Poles 2 2
Current Rating (amps) 100 200
60 Hz Phase Single Single
Voltage Rating (VAC) 250 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%

80%
60%
Return to Utility 15 seconds 15 seconds
Service Disconnect Circuit Breaker 100 Amp HACR Type 200 Amp HACR Type
Exerciser 15 min. weekly * Standard Standard
UL 1008 Listed Standard Standard
Dimensions (H"xW"xD") 23.5x13x7.4 23.5x13x7.4
Enclosure Type NEMA 3R
Outdoor Rated
NEMA 3R
Outdoor Rated
Unit Wt. (lbs.) 50 50

* When used with liquid-cooled models. If used with air-cooled models exercise duration will be 12 minutes.

 
GENERATOR READY KIT
Model Number 04397
No. of Poles 2
Current Rating (amps) 100
60 Hz Phase Single
Voltage Rating (VAC) 250
Utility Voltage Monitor (fixed)
Pick-up
Dropout

80%
60%
Return to Utility 15 seconds
Exerciser 12 min. weekly † Standard
UL 1008 Listed Standard
Dimensions (H"xW"xD") 26.5x12.5x7
Enclosure Type NEMA 1
Indoor Rated
Unit Wt. (lbs.) 75

When used with air-cooled standby generator models. No exercise function takes place when used with the Ultra Source portable generators.

Transfer Switches for the Generac Guardian Generators ATS | Home

Copyright 2005 Bestgenerators.com   |  Legal Notices

30kW - 3.0L Liquid Cooled 40kW - 3.9L Liquid Cooled 50kW - 3.0L Liquid Cooled 55kW - 5.4L Liquid Cooled 70kW - 3.9L Liquid Cooled 70kW - 6.8L Liquid Cooled 80kW - 5.4L Liquid Cooled 100kW - 5.4L Liquid Cooled 100kW - 6.8L Liquid Cooled 130kW - 6.8L Liquid Cooled 150kW - 6.8L Liquid Cooled 11 kW 15, 20 & 25 kW 30 kW & 40 kWTransfer Switches  |  Generator Control Panel